Human Serum Albumin EIA Kit
Cayman Chemical Item Number 500340
Albumin (human serum) EIA Kit; HSA ELISA Kit
Human Serum Albumin EIA Kit
See analysis tools…
Human Serum Albumin EIA Kit Analysis Tools
Cayman offers a variety of analysis tools to assist you.
Description
Limit of detection:
80% B/B0: 65 pg/ml
·
Sensitivity:
50% B/B0: 250 ng/ml
·
The measurement of albumin in urine is well established clinically as an indicator of renal function. Approximately fifty percent of human blood serum protein is albumin. Albumin (human serum) (HSA) has many important physiological functions including maintaining osmotic pressure, buffering pH of the blood, and the transport of hormones, fatty acids, and other molecules throughout the body. Elevated levels of albumin (microalbuminuria and macroalbuminuria) in the urine are an indication of various disease states including diabetic nephropathy, non-diabetic kidney disease, and cardiovascular morbidity and mortality.1,2,3 Normal urinary HSA levels of adults are less than 30 µg albumin per mg of creatinine. Microalbuminuria is defined as 30-300 µg albumin per mg of creatinine and Macroalbuminuria is defined as albumin levels greater than 300 µg/mg.4,5 Cayman’s HSA EIA Kit is a competitive assay that can be used for quantification of HSA in urine. The EIA typically displays an IC50 (50% B/B0) of aproximately 250 ng/ml and a detection limit (80% B/B0) of approximately 60 ng/ml.
1
Hovind, P., Tarnow, L., Rossing, P., et al. Predictors for the development of microalbuminuria and macroalbuminuria in patients with type 1 diabetes: inception cohort study. BMJ 328 1105-1110 (2004).
2
Damsgaard, E.M., Froland, A., Jorgensen, O.D., et al. Microalbuminuria as predictor of increased mortality in elderly people. Br Med J 300 297-300 (1990).
3
Brinkman, J.W., de Zeeuw, D., Duker, J.J., et al. Falsely low urinary albumin concentrations after prolonged frozen storage of urine samples. Clin Chem 51(11) 2181-2183 (2005).
4
Justesen, T.I., Petersen, J.L.A., Ekbom, P., et al. Albumin-to-creatinine ratio in random urine samples might replace 24-h urine collections in screening for micro- and macroalbuminuria in pregnant woman with type 1 diabetes. Diabetes Care 29(4) 924-925 (2006).
5
Ruggenenti, P., Gaspari, F., Perna, A., et al. Cross sectional longitudinal study of spot morning urine protein: Creatinine ratio, 24 hour urine protein excretion rate, glomerular filtration rate, and end stage renal failure in chronic renal disease in patients without diabetes. BMJ 316 504-509 (1998).
| Synonyms |
- Albumin (human serum) EIA Kit
- HSA ELISA Kit
|
| Stability |
1 year |
| Storage |
-20°C |
| Shipping |
Wet ice
in continental US; may vary elsewhere
|
| Specificity |
| urine Human Serum Albumin |
100% |
|
Background Reading
Hovind, P., Tarnow, L., Rossing, P., et al. Predictors for the development of microalbuminuria and macroalbuminuria in patients with type 1 diabetes: inception cohort study. BMJ 328 1105-1110 (2004).
Damsgaard, E.M., Froland, A., Jorgensen, O.D., et al. Microalbuminuria as predictor of increased mortality in elderly people. Br Med J 300 297-300 (1990).
Brinkman, J.W., de Zeeuw, D., Duker, J.J., et al. Falsely low urinary albumin concentrations after prolonged frozen storage of urine samples. Clin Chem 51(11) 2181-2183 (2005).
Justesen, T.I., Petersen, J.L.A., Ekbom, P., et al. Albumin-to-creatinine ratio in random urine samples might replace 24-h urine collections in screening for micro- and macroalbuminuria in pregnant woman with type 1 diabetes. Diabetes Care 29(4) 924-925 (2006).
Ruggenenti, P., Gaspari, F., Perna, A., et al. Cross sectional longitudinal study of spot morning urine protein: Creatinine ratio, 24 hour urine protein excretion rate, glomerular filtration rate, and end stage renal failure in chronic renal disease in patients without diabetes. BMJ 316 504-509 (1998).
Show all 5
Hide all but first 3
|
- All 480 well kits are supplied with a single 500 dtn vial of tracer and antiserum that must be used within the stated time following reconstitution.
- Check the Additional Items Required section of this kit booklet to verify if UltraPure Water (Milli-Q or equivalent) is needed for this assay.
Pricing updated 2012-02-12.
Prices are subject to change without notice.
To ask for assistance with one of our products please contact a Technical Support Scientist.
Warning This product is not for human or veterinary use.
You may be eligible to receive a free sample Human Serum Albumin EIA Kit under the Cayman Challenge program.
Let Cayman analyze your samples for you. See EIA Service for details and availability.
Show all 4
Hide all but first 3
Downloads
Batch-specific Information
Login
to access batch-specific information
|