See personalized New Product recommendations! Get personalized New Product recommendations! Register or Login for personalized New Product recommendations!

Join us! · InformexUSA 2012 · New Orleans, Louisiana · February 14-17, 2012 · Booth 2514

8-hydroxy-2-deoxy Guanosine EIA Kit

Cayman Chemical Item Number 589320

DNA Damage EIA Kit; 8-OH-dG ELISA Kit

8-hydroxy-2-deoxy Guanosine EIA Kit

See analysis tools…

8-hydroxy-2-deoxy Guanosine EIA Kit Analysis Tools

Cayman offers a variety of analysis tools to assist you.

See more

Description

Limit of detection: 80% B/B0: ~30 pg/ml · Sensitivity: 50% B/B0: ~100 pg/ml · 8-hydroxy-2-deoxy Guanosine (8-OH-dG) is a product of oxidative damage of DNA by reactive oxygen and nitrogen species and serves as an established marker of oxidative stress. Hydroxylation of guanosine occurs in response to both normal metabolic processes and a variety of environmental factors. Increased levels of 8-OH-dG are associated with the aging process as well as with a number of pathological conditions including cancer, diabetes, and hypertension. Cayman’s 8-OH-dG EIA is a competitive assay that can be used for the quantification of 8-OH-dG in urine, cell culture, plasma, and other sample matrices. The EIA utilizes an anti-mouse IgG-coated plate and a tracer consisting of an 8-OH-dG-enzyme conjugate. This format has the advantage of providing low variability and increased sensitivity compared to assays that utilize an antigen-coated plate. Our EIA typically displays IC50 (50% B/B0) and IC80 (80% B/B0) values of approximately 100 and 30 pg/ml, respectively. It is important to note that the 8-OH-dG antibody used in this assay recognizes both free 8-OH-dG and DNA-incorporated 8-OH-dG. Since complex samples such as plasma, cell lysates, and tissues are comprised of mixtures of DNA fragments and free 8-OH-dG, concentrations of 8-OH-dG reported by EIA methodology will not coincide with those reported by LC-MS where the single nucleoside is typically measured. This should be kept in mind when analyzing and interpreting experimental results.
Synonyms
  • DNA Damage EIA Kit
  • 8-OH-dG ELISA Kit
Stability 1 year
Storage -20°C
Shipping Wet ice in continental US; may vary elsewhere
Specificity
8-hydroxy-2-deoxy Guanosine 100%
8-hydroxy Guanosine 23%
8-hydroxy Guanine 23%
Guanosine <0.01%
Show all 4 Hide all but first 3

Background Reading

Kuo, H., Chou, S., Hu, T., et al. Urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG) and genetic polymorphisms in breast cancer patients. Mutat Res 631 62-68 (2007).

Pradelles, P., Grassi, J., and Maclouf, J. Enzyme immunoassays of eicosanoids using acetylcholinesterase. Methods Enzymol 187 24-34 (1990).

Maxey, K.M., Maddipati, K.R., and Birkmeier, J. Interference in enzyme immunoassays. J Clin Immunoassay 15 116-120 (1992).

Floyd, R.A. Role of oxygen free radicals in carcinogenesis and brain ischemia. FASEB J 4 2587-2597 (1990).

Spencer, J.P.E., Jenner, A., Chimel, K., et al. DNA strand breakage and base modification induced by hydrogen peroxide treatment of human respiratory tract epithelial cells. FEBS Lett 374 233-236 (1995).

Epe, B., Ballmaier, D., Roussyn, I., et al. DNA damage by peroxynitrite characterized with DNA repair enzymes. Nucleic Acids Res 24 4105-4110 (1996).

Beckman, K.B., and Ames, B.N. Oxidative decay of DNA. J Biol Chem 272 19633-19636 (1997).

Shen, J., Deininger, P., Hunt, J.D., et al. 8-hydroxy-2'-deoxyguanosine (8-OH-dG) as a potential survival biomarker in patients with nonsmall-cell lung cancer. Cancer 109 574-580 (2007).

Endo, K., Miyashita, Y., Sasaki, H., et al. Probucol and atorvastatin decrease urinary 8-hydroxy-2'-deoxyguanosine in patients with diabetes and hypercholesterolemia. J Atheroscler Thromb 13 68-75 (2006).

Leinonen, J., Lehtimäki, T., Toyokuni, S., et al. New biomarker evidence of oxidative DNA damage in patients with non-insulin-dependent diabetes mellitus. FEBS Lett 417 150-152 (1997).

Lee, J., Lee, M., Kim, J., et al. Carvedilol reduces plasma 8-hydroxy-2'-deoxyguanosine in mild to moderate hypertension. A pilot study. Hypertension 45 986-990 (2005).

Bogdanov, M.B., Beal, M.F., McCabe, D.R., et al. A carbon column-based liquid chromatography electrochemical approach to routine 8-hydroxy-2'-deoxyguanosine measurements in urine and other biologic matrices: A one-year evaluation of methods. Free Radic Biol Med 27(5/6) 647-666 (1999).

Lin, H., Jenner, A.M., Ong, C.N., et al. A high-throughput and sensitive methodology for the quantification of urinary 8-hydroxy-2'-deoxyguanosine: Measurement with gas chromatography-mass spectrometry after single solid-phase extraction. Biochem J 380 541-548 (2004).

Maclouf, J., Grassi, J., and Pradelles, P. Development of enzyme-immunoassay techniques for the measurement of eicosanoids. 355-364 (1987).

Show all 14 Hide all but first 3
589320-96SOLID
8-hydroxy-2-deoxy Guanosine AChE Tracer 100 dtn
8-hydroxy-2-deoxy Guanosine EIA Monoclonal Antibody 100 dtn
8-hydroxy-2-deoxy Guanosine EIA Standard 1 ea
Precoated (Goat Anti-Mouse IgG) EIA 96-Well Solid Plate 1 ea
Polysorbate 20 1 ea
EIA Tracer Dye 1 ea
EIA Antiserum Dye 1 ea
Ellman's Reagent 3 × 100 dtn
EIA Buffer Concentrate (10X) 2 × 10 mL
Wash Buffer Concentrate (400X) 5 mL
589320-96well
8-hydroxy-2-deoxy Guanosine AChE Tracer 100 dtn
8-hydroxy-2-deoxy Guanosine EIA Monoclonal Antibody 100 dtn
8-hydroxy-2-deoxy Guanosine EIA Standard 1 ea
Precoated (Goat Anti-Mouse IgG) EIA 96-Well Strip Plate 1 ea
Polysorbate 20 1 ea
EIA Tracer Dye 1 ea
EIA Antiserum Dye 1 ea
Ellman's Reagent 3 × 100 dtn
EIA Buffer Concentrate (10X) 2 × 10 mL
Wash Buffer Concentrate (400X) 5 mL
589320-480well
8-hydroxy-2-deoxy Guanosine AChE Tracer 500 dtn
8-hydroxy-2-deoxy Guanosine EIA Monoclonal Antibody 500 dtn
8-hydroxy-2-deoxy Guanosine EIA Standard 1 ea
Precoated (Goat Anti-Mouse IgG) EIA 96-Well Strip Plate 5 ea
Polysorbate 20 1 ea
EIA Tracer Dye 1 ea
EIA Antiserum Dye 1 ea
Ellman's Reagent 6 × 250 dtn
EIA Buffer Concentrate (10X) 4 × 10 mL
Wash Buffer Concentrate (400X) 12.5 mL
589320-480SOLID
8-hydroxy-2-deoxy Guanosine AChE Tracer 500 dtn
8-hydroxy-2-deoxy Guanosine EIA Monoclonal Antibody 500 dtn
8-hydroxy-2-deoxy Guanosine EIA Standard 1 ea
Precoated (Goat Anti-Mouse IgG) EIA 96-Well Solid Plate 5 ea
Polysorbate 20 1 ea
EIA Tracer Dye 1 ea
EIA Antiserum Dye 1 ea
Ellman's Reagent 6 × 250 dtn
EIA Buffer Concentrate (10X) 4 × 10 mL
Wash Buffer Concentrate (400X) 12.5 mL
Size Price Quantity Subtotal
96 solid wells $420.00 $0.00
96 strip wells $420.00 $0.00
480 solid wells $1,575.00 $0.00
480 strip wells $1,575.00 $0.00
Bulk Contact
Cart Total $0.00

This product is also available to buy in bulk quantities.

Please contact our Sales Department for a quote or to purchase.

  • All 480 well kits are supplied with a single 500 dtn vial of tracer and antiserum that must be used within the stated time following reconstitution.
  • Check the Additional Items Required section of this kit booklet to verify if UltraPure Water (Milli-Q or equivalent) is needed for this assay.

Pricing updated 2012-02-10. Prices are subject to change without notice.

To ask for assistance with one of our products please contact a Technical Support Scientist.

Warning This product is not for human or veterinary use.

You may be eligible to receive a free sample 8-hydroxy-2-deoxy Guanosine EIA Kit under the Cayman Challenge program.

Let Cayman analyze your samples for you. See EIA Service for details and availability.

Related Products

8-Isoprostane EIA Kit
Aconitase Fluorometric Assay Kit New
Antioxidant Assay Kit
Ascorbate Assay Kit
Catalase Assay Kit
Glutathione Assay Kit
Lipid Hydroperoxide (LPO) Assay Kit
L-Theanine Fluorometric Assay Kit Exclusive
Protein Carbonyl Assay Kit
Protein Carbonyl Fluorometric Assay Kit
Superoxide Dismutase Assay Kit
TBARS Assay Kit
UltraPure Water
Show all 13 Hide all but first 3

Downloads

Batch-specific Information

Login to access batch-specific information

FAQs

The the level of 8-OH-dG has been estimated in cultured cells after extracting total DNA. What is the best way to normalize the data for accurate comparison between treatments?

It is more meaningful to normalize measured values to the total number of cells, or the amount of purified DNA rather than as a concentration of 8-OH-dG only.

Show answer Hide answer

Has the 8-hydroxy-2-deoxy Guanosine EIA Kit been validated for muscle tissue or whole blood (leukocyte DNA) samples?

The 8-hydroxy-2-deoxy Guanosine EIA Kit has not been validated for those exact sample types, but has been validated for cell lysates and tissue homogenates in general. Theoretically, the kit should work just fine with any purified DNA sample.

Show answer Hide answer

Cayman Chemical is a manufacturer, supplier and vendor of biochemical reagents, assay kits, antibodies, and proteins.

Other Resources
Management Team Company Profile Company History ChemAssistant Tools FAQs Cayman Europe Cayman Pharma CaBRI Cayman Gear Press Releases Illustrations and Charts Key Research Area Posters Article Library Analysis Tools Conference Schedule Order Terms Browser Recommendation Privacy Statement Site Map

Cayman Chemical Company · 1180 East Ellsworth Road · Ann Arbor, Michigan 48108 · USA

Toll Free: (800) 364-9897 (USA and Canada Only) · Fax: (734) 971-3640

Copyright 2012 Cayman Chemical Company

Lost password?