Visit our FAQ
Toll Free Phone (USA and Canada Only): (888) 526-5351
Direct Phone: (734) 975-3888
Product Categories
Product Type
Provide batch numbers separated by commas to download or request available product inserts, QC sheets, certificates of analysis, data packs, and GC-MS data.
This assay utilizes proprietary human cells that have been engineered to provide constitutive expression of the Human Oxytocin Receptor (OXTR).
Upon activation by its physiological ligand oxytocin, OXTR activates Gαq/11 to mediate several downstream pathways. This includes activation of the phospholipase C (PLC) pathway, which leads to the release of inositol triphosphate (IP3), resulting in the increase of intracellular calcium and the concomitant activation of calcineurin, a calcium-dependent phosphatase. Ca+2-calcineurin acts to dephosphorylate and activate the transcription factor NFAT11. OXTR activation of the Ca+2-calcineurin > NFAT cascade is the signal transduction pathway exploited by the reporter cells provided in this kit.
INDIGO's OXTR Reporter Cells contain an engineered luciferase reporter gene functionally linked to tandem consensus sequences of the NFAT genetic response elements and a minimal promoter. Activated NFAT binds to these response elements to seed the formation of a complete transcription complex that drives luciferase reporter gene expression. Quantifying relative changes in luciferase activity in the treated reporter cells relative to the untreated cells provides a sensitive surrogate measure of drug-induced changes in OXTR activity.
The principal application of this reporter assay is in the screening of test samples to quantify functional interactions, either activating or inhibitory, that they may exert against OXTR, or the coupled Ca+2∙calcineurin / NFAT signal transduction pathway.
INDIGO’s Reporter Cells are transiently transfected and prepared as frozen stocks using a proprietary CryoMite™ process. This cryo-preservation method allows for the immediate dispensing of healthy, division-competent reporter cells into assay plates. There is no need for intermediate treatment steps such as spin-and-rinse of cells, extended pre-culture, viability determinations, or cell titer adjustments prior to assay setup.
INDIGO's assay kits provide the convenience of an all-inclusive cell-based assay system. In addition to OXTR Reporter Cells, provided are two optimized media for use in recovering the cryopreserved cells and for diluting test samples, the reference activator Oxytocin, Luciferase Detection Reagents, and a cell culture-ready assay plate. [INDIGO Catalog Nos. IB35001 | IB35002]
WARNING This product is not for human or veterinary use.